Planning Atlas
Planning AtlasHammersmith And FulhamFulham Reach wardW6 8RF2021/03211/FUL
Planning application · Hammersmith And Fulham

2021/03211/FUL.

Charing Cross Hospital Fulham Palace Road London W6 8RF

Full / Other Planning at Charing Cross Hospital Fulham Palace Road London W6 8RF, received 6 Oct 2021 — approved on 19 Jul 2022 (delegated, Mwansa Tembo).

ApprovedRefusedOther
At a glance · this applicationHammersmith And Fulham profile →
Approved
Outcome
19 Jul 2022
41 wks
Decision time
33 wks over the 8-week target
Conditions
not captured
27
Documents
27 linked
0
Objections
not captured
No
Appeal
none recorded
Record from the Hammersmith And Fulham planning register as captured; documents link to the council's own files. Nearby applications are context, not part of this application.
Application

What is it?

Installation and screening of 2no. new air source combo heat pumps on the roof of the Oncology Building; installation and screening of 2no. new air source combo heat pumps on the roof of the X-ray Building; installation of an external plant area on a raised deck adjacent to the Tower block; installation of a new substation; and installation of pipework to existing external fabric to serve all new heat pumps, including to the full extent of the north elevation of the Tower Block from ground up to the 17th floor.

Reference
2021/03211/FUL
Type
Full Planning Application
Agent / consultant
Case officer
Postcode
Received
6 Oct 2021
Validated
14 Oct 2021
Target date
19 Jul 2025
Decision date
19 Jul 2022
Decision route
Not recorded
Status
Final Decision
Reference
2021/03211/FUL
Type
Full Planning Application
Show all 16 rows
Agent / consultant
Case officer
Postcode
Received
6 Oct 2021
Validated
14 Oct 2021
Target date
19 Jul 2025
Decision date
19 Jul 2022
Decision route
Not recorded
Status
Final Decision
Documents

What was filed?

Document
Published
View
13-EMS266-XB-ZZ-DR-Z-300---X-RAY-BUILDING-PROPOSED-NORTH-ELE
24-1091-102-SUB-STATION-PROPOSED-ROOF-PLAN
4-CXH-P8417-3_DESIGN-RISK-ASSESSMENT-(T2)---SUBSTATION
10-EMS266-TB-LG-DR-M-301---LOWER-GROUND-FLOOR-EXTERNAL-PLANT
20-1091-02---SUB-STATION-EXISITNG-GND-AND-1ST-FLOOR
22-1091-04---SUB-STATION-EXISTING-ELEV---SECT
18-AA205LS---HEAT-PUMP-ACOUSTIC-ENCLOSURE-TYPICAL-ARRANGEMEN
25-1091-103-SUB-STATION-PROPOSED-ELEVATIONS
19-1091-01---SUB-STATION-SITE-PLAN
21-1091-03---SUB-STATION-EXISTING-ROOF
13-EMS266-XB-ZZ-DR-Z-300---X-RAY-BUILDING-PROPOSED-NORTH-ELE
24-1091-102-SUB-STATION-PROPOSED-ROOF-PLAN
4-CXH-P8417-3_DESIGN-RISK-ASSESSMENT-(T2)---SUBSTATION
Show all 10 rows
10-EMS266-TB-LG-DR-M-301---LOWER-GROUND-FLOOR-EXTERNAL-PLANT
20-1091-02---SUB-STATION-EXISITNG-GND-AND-1ST-FLOOR
22-1091-04---SUB-STATION-EXISTING-ELEV---SECT
18-AA205LS---HEAT-PUMP-ACOUSTIC-ENCLOSURE-TYPICAL-ARRANGEMEN
25-1091-103-SUB-STATION-PROPOSED-ELEVATIONS
19-1091-01---SUB-STATION-SITE-PLAN
21-1091-03---SUB-STATION-EXISTING-ROOF

Documents open on the Hammersmith And Fulham portal. View the application page ↗

Decision

What happened?

Approved on 19 Jul 2022, delegated decision by Mwansa Tembo — 41 weeks from submission (33 over the 8-week target).

Timeline

Date
Event
6 Oct 2021
Application received
14 Oct 2021
Application validated
19 Jul 2025
Statutory target date
19 Jul 2022
Delegated decision: Approved · Mwansa Tembo
6 Oct 2021
Application received
14 Oct 2021
Application validated
19 Jul 2025
Statutory target date
Show all 4 rows
19 Jul 2022
Delegated decision: Approved · Mwansa Tembo

Public response

Measure
Count
Objections
0
Objections
0
People

Who is involved?

Name
Role
Applicant — the party who applied, not necessarily the owner
Agent · consultant profile
Case officer — delegated decision
Applicant — the party who applied, not necessarily the owner
Agent · consultant profile
Case officer — delegated decision
Place

What affects it?

Context around the site — not part of this application. Designations over the site: use the map's designations filter (conservation areas, listed buildings, Article 4, flood risk …). Decisions within 250 metres of the site are listed below — context, not this application.

Other applications within 250 metres (context — nearby, not this application)

No other geocoded decision is recorded within 250 metres.